Wednesday, September 25, 2019

2019 Infiniti M35 V6-3.5L (VQ35HR) Diagnostic and Repair Information Page 664

2019 Infiniti M35 V6-3.5L (VQ35HR) Diagnostic and Repair Information Page 664



3. Disconnect battery negative cable (1).



Black arrow: To body ground



4. Install jumper cable (A) between battery negative terminal and body ground.



5. Turn ignition switch ON.



6. Check the voltage between ECM harness connector terminals under the following conditions.



Is the inspection result normal?



YES - INSPECTION END



NO - Replace battery negative cable assembly.



P1554



P1554 BATTERY CURRENT SENSOR



Description



The power generation voltage variable control enables fuel consumption to be decreased by reducing the engine load which is caused by the



power generation of the generator. The battery current sensor is installed to the battery cable at the negative terminal. The sensor measures the



charging/discharging current of the battery. Based on the sensor signal, ECM judges whether or not the power generation voltage variable control



is performed. When performing the power generation voltage variable control, ECM calculates the target power generation voltage based on the



sensor signal. And ECM sends the calculated value as the power generation command value to IPDM E/R. For the details of the power generation



voltage variable control, See: Starting and Charging/Charging System/Description and Operation.



CAUTION:



Never connect the electrical component or the ground wire directly to the battery terminal. The connection causes the malfunction of the



power generation voltage variable control, and then battery discharge may occur.